Reduced Energy Cost: Extended operational life of the heat exchanger ensures that the units provide the lowest long term cost benefits. It offers a self-adapting optimum start and stop. Simple user-friendly programming. Individual seven-day programming options. Day, night and frost (5˚C) temperature settings. Modulating burner control
Versatile Fuel Options: All units are available for natural gas (G20, G25, G25.3)
Wide Range of Applications: From Automotive workshops, Factories, Retail outlets, Sports arenas and halls, Warehouses, Workshops
Optimum Efficiency: Photon and Photon-B unitsincorporate 4-pass heat exchangertechnology for optimum efficiencyand enhanced life expectancy
Single Burner: Single burner with multi-try ignition provides enhanced reliability
Available In Ten Separate Heat Outputs: Ranging from 9.34kW, 18.39kW, 26.54kW, 31.68kW, 42.24kW, 53.46kW, 63.59kW, 71.25kW, 97.87kW, 120.16kW
Optimised Control Options: The Smartcom panel, available separately, offers a wide array of control options. With a simple user-friendly programming, self-adapting optimum start and stop and many more options available
The Photon is the very latest in suspended gas fired heaters. Designed specifically for use in large commercial, industrial and retail spaces. This unit will provide constant heat distribution in any applied area from Automotive workshops, factories, retail outlets, Sports arenas and halls, warehouses and workshops.
This suspended gas fired unit offers ten model heat output options ranging from 9.34kW, 18.39kW, 26.54kW, 31.68kW, 42.24kW, 53.46kW, 63.59kW, 71.25kW, 97.87kW, 120.16kW. Each Photon device is fitted with a high airflow axial fan. This allows the heater free-blowing applications.
A modulating burner is fitted to each model in the range, (Requires a 0 to 10v DC signal to operate.) The single burner with multi-try ignition provides enhanced reliability during operation. All the gas fire heaters are also operable using G20, G25, G25.3, natural gas.
The Smartcom control panel is a complimentary optional addition that provides greater levels of operational functionality to the Photon. Three on/off periods per day. Easy set overtime and holiday periods Remote burner reset facility. Password protection to prevent unauthorised adjustment. Hours run and service data logging. Battery back up in the event of mains failure.
See More Like This: Suspended Heaters
Model Photon 10
Combustion Air and Flue Type 1 B23 / B53 / C13 / C33 / C53
Heat Output High Fire 2 kW 9.34
Gas Consumption High Fire (HS) G20 3 m3/h 1.07
Gas Consumption High Fire (HS) G25 3 m3/h 1.25
Gas Consumption High Fire (HS) G25.3 3 m3/h 1.22
Gas Connection 4 BSP ½"
Airflow m3/h 1223
Horizontal Throw m 10
Noise Level 5 dBA 46
Minimum mounting height m 2.5
Recommended mounting height 6 m 3.0
Total Electrical Rating W 145
Electrical Connection 230V / 1N / 50Hz
Protection Grade IP IP20
Net weight Kg 43
Model Photon 20
Combustion Air and Flue Type 1 B23 / B53 / C13 / C33 / C53
Heat Output High Fire 2 kW 18.39
Gas Consumption High Fire (HS) G20 3 m3/h 2.14
Gas Consumption High Fire (HS) G25 3 m3/h 2.49
Gas Consumption High Fire (HS) G25.3 3 m3/h 2.44
Gas Connection 4 BSP ½"
Airflow m3/h 2533
Horizontal Throw m 16
Noise Level 5 dBA 48
Minimum mounting height m 2.5
Recommended mounting height 6 m 3.0
Total Electrical Rating W 150
Electrical Connection 230V / 1N / 50Hz
Protection Grade IP IP20
Net weight Kg 63
Model Photon 25
Combustion Air and Flue Type 1 B23 / B53 / C13 / C33 / C53
Heat Output High Fire 2 kW 26.54
Gas Consumption High Fire (HS) G20 3 m3/h 3.08
Gas Consumption High Fire (HS) G25 3 m3/h 3.59
Gas Consumption High Fire (HS) G25.3 3 m3/h 3.51
Gas Connection 4 BSP ½"
Airflow m3/h 3035
Horizontal Throw m 26
Noise Level 5 dBA 49
Minimum mounting height m 2.5
Recommended mounting height 6 m 4.0
Total Electrical Rating W 254
Electrical Connection 230V / 1N / 50Hz
Protection Grade IP IP20
Net weight Kg 58
Model Photon 35
Combustion Air and Flue Type 1 B23 / B53 / C13 / C33 / C53
Heat Output High Fire 2 kW 31.68
Gas Consumption High Fire (HS) G20 3 m3/h 3.69
Gas Consumption High Fire (HS) G25 3 m3/h 4.30
Gas Consumption High Fire (HS) G25.3 3 m3/h 4.20
Gas Connection 4 BSP 3/4"
Airflow m3/h 4120
Horizontal Throw m 27
Noise Level 5 dBA 51
Minimum mounting height m 2.5
Recommended mounting height 6 m 4.0
Total Electrical Rating W 550
Electrical Connection 230V / 1N / 50Hz
Protection Grade IP IP20
Net weight Kg 89
Model Photon 45
Combustion Air and Flue Type 1 B23 / B53 / C13 / C33 / C53
Heat Output High Fire 2 kW 42.24
Gas Consumption High Fire (HS) G20 3 m3/h 4.91
Gas Consumption High Fire (HS) G25 3 m3/h 5.71
Gas Consumption High Fire (HS) G25.3 3 m3/h 5.59
Gas Connection 4 BSP 3/4"
Airflow m3/h 4562
Horizontal Throw m 26
Noise Level 5 dBA 51
Minimum mounting height m 2.5
Recommended mounting height 6 m 4
Total Electrical Rating W 550
Electrical Connection 230V / 1N / 50Hz
Protection Grade IP IP20
Net weight Kg 99
Model Photon 55
Combustion Air and Flue Type 1 B23 / B53 / C13 / C33 / C53
Heat Output High Fire 2 kW 53.46
Gas Consumption High Fire (HS) G20 3 m3/h 6.17
Gas Consumption High Fire (HS) G25 3 m3/h 7.17
Gas Consumption High Fire (HS) G25.3 3 m3/h 7.02
Gas Connection 4 BSP 3/4"
Airflow m3/h 5877
Horizontal Throw m 32
Noise Level 5 dBA 51
Minimum mounting height m 2.5
Recommended mounting height 6 m 4
Total Electrical Rating W 690
Electrical Connection 230V / 1N / 50Hz
Protection Grade IP IP20
Net weight Kg 121
Model Photon 65
Combustion Air and Flue Type 1 B23 / B53 / C13 / C33 / C53
Heat Output High Fire 2 kW 63.59
Gas Consumption High Fire (HS) G20 3 m3/h 7.37
Gas Consumption High Fire (HS) G25 3 m3/h 8.57
Gas Consumption High Fire (HS) G25.3 3 m3/h 8.39
Gas Connection 4 BSP 3/4"
Airflow m3/h 7125
Horizontal Throw m 32
Noise Level 5 dBA 56
Minimum mounting height m 2.5
Recommended mounting height 6 m 4
Total Electrical Rating W 820
Electrical Connection 230V / 1N / 50Hz
Protection Grade IP IP20
Net weight Kg 122
Model Photon 70
Combustion Air and Flue Type 1 B23 / B53 / C13 / C33 / C53
Heat Output High Fire 2 kW 71.25
Gas Consumption High Fire (HS) G20 3 m3/h 8.19
Gas Consumption High Fire (HS) G25 3 m3/h 9.52
Gas Consumption High Fire (HS) G25.3 3 m3/h 9.32
Gas Connection 4 BSP 3/4"
Airflow m3/h 8681
Horizontal Throw m 36
Noise Level 5 dBA 59
Minimum mounting height m 2.5
Recommended mounting height 6 m 4
Total Electrical Rating W 1000
Electrical Connection 230V / 1N / 50Hz
Protection Grade IP IP20
Net weight Kg 135
Model Photon 100
Combustion Air and Flue Type 1 B23 / B53 / C13 / C33 / C53
Heat Output High Fire 2 kW 97.87
Gas Consumption High Fire (HS) G20 3 m3/h 11.33
Gas Consumption High Fire (HS) G25 3 m3/h 13.18
Gas Consumption High Fire (HS) G25.3 3 m3/h 12.89
Gas Connection 4 BSP 3/4"
Airflow m3/h 10350
Horizontal Throw m 36
Noise Level 5 dBA 60
Minimum mounting height m 2.5
Recommended mounting height 6 m 4.0 - 5.0
Total Electrical Rating W 1040
Electrical Connection 230V / 1N / 50Hz
Protection Grade IP IP20
Net weight Kg 168
Model Photon 120
Combustion Air and Flue Type 1 B23 / B53 / C13 / C33 / C53
Heat Output High Fire 2 kW 120.16
Gas Consumption High Fire (HS) G20 3 m3/h 13.71
Gas Consumption High Fire (HS) G25 3 m3/h 15.94
Gas Consumption High Fire (HS) G25.3 3 m3/h 15.6
Gas Connection 4 BSP 1"
Airflow m3/h 17552
Horizontal Throw m 36
Noise Level 5 dBA 62
Minimum mounting height m 2.5
Recommended mounting height 6 m 4.0 - 5.0
Total Electrical Rating W 1900
Electrical Connection 230V / 1N / 50Hz
Protection Grade IP IP20
Net weight Kg 258